Categories

Manufacturers

Qubino 3-Phase Smart Meter (ZMNHXD1)

GOA-ZMNHXD1-452

New product

  • Qubino 3-Phase Smart Meter is used for energy measurements in three-phase electrical power network and can be used in residential, industrial and utility applications.
  • The device measures energy directly in 4-wire networks according to the principle of fast sampling of voltage and current signals.
  • It is designed to be mounted on DIN rail.

More details

175,41 € tax incl.

194,90 € tax incl.


146,18 € tax excl.
Oops, this product is currently out of stock
 
More info

Qubino 3-Phase Smart Meter (ZMNHXD1)

The Z-Wave Plus Qubino 3-Phase Smart Meter DIN-Module is intended to be used for energy measurements in three-phase electrical power network installations and can be used in residential, industrial and utility applications. The Qubino 3-Phase Smart Meter measures energy directly in 4-wire networks according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates energy, power and power factor from the measured signals.

The Qubino 3-Phase Smart Meter DIN-Module can be controlled through Z-wave network and it acts as a repeater in order to improve the range and stability of a Z-wave network. The Module is designed to be mounted on DIN-Rail.

Technical Details:

Main terminals (L1I, L2I, L3I, NO, L1O, L2O, L3O, NO)

  • Contacts capacity: 2.5 ... 16 (25) mm2
  • Connection screws: M5
  • Max torque: 3.5 Nm (PZ2)

Optional terminals (DI, DO)

  • Contact capacity: 1 ... 2.5 mm2
  • Screws: M3
  • Max torque: 1.2 Nm

Measuring input

  • Type (connection): three phase (4u)
  • Basic current (Ib): 5 A
  • Maximum current (Imax): 80 A
  • Minimum current (Imin): 0.25 A
  • Starting current: 20 mA
  • Reference Voltage (Un): 3x230 V / 400V
  • Power consumption at Un < 8VA
  • Nominal frequency (fn): 50 and 60 Hz

Accuracy

Active energy and power

  • Standard EN 62053-21 class 1
  • Standard EN 50470-3 class B

Reactive energy

  • Standard EN 62053-23 Class 2

LED

  • Colour: red
  • Pulse rate: 500 imp/kWh
  • Led on: no load indication

Optical communication

  • Type IR - used to control BICOM432-40-WM1

Input (16)

  • Rated voltage: 230 V (± 20%)
  • Input resistance: 450 kOhm

LCD

  • Display 7+1 digit (100Wh resolution)

Safety

  • Indoor Meter: yes
  • Degree of pollution: 2
  • Protection class: II
  • AC voltage test: 4 kV
  • Installation Category: 300 Vrms cat. III
  • Standard: EN 50470

Ambient conditions and EMC

  • According standards for indoor active energy meters.
  • Temperature and climatic condition according to EN 62052-11

Ambient conditions and Safety:

  • According standards for indoor active energy meters.
  • Temperature and climatic condition according to EN 62052-11
  • Dust/water protection: IP20
  • Operation temperature: -10 ... 55°C
  • Storage temperature: -40 ... 70°C
  • Enclosure material self extinguish, complying UL94 V
  • Indoor meter: yes
  • Degree of pollution: 2
  • Protection class: II
  • AC voltage test: 4 kV
  • Installation Category: 300 Vrms cat. III
  • Standard: EN 50470
  • Distance: up to 30 m indoors (depending on building materials)
  • Weight: 220g
  • Brutto weight (packaging included): 240g
  • Installation: DIN rail 35mm (EN 60715)
  • Dimensions: (W x H x D) 53,6 x 84 x 65mm
  • Package dimensions (W x H x D): 56 x 86 x 70mm
  • Colour: RAL 7035
 
Data sheet
Brand IDQUBINO
HS CODE90283019000
Z-Wave technologyZ-Wave Plus (Gen 5) 868.42 MHz
IoT - Internet of ThingsWireless communication
Energy MeteringPower Metering
Neutral wireRequired
Power SupplyCable Power
Type of useIndoor
IP RatingIP20
Compatibility with HOMEYNo
Compatibility with FIBARO HC3Not Tested
FIBARO HC2 CompatibilityNot Tested
FIBARO HC LITE CompatibilityNot Tested
VERA PLUS CompatibilityNot Tested
VERA EDGE CompatibilityNot Tested
ZIPABOX CompatibilityNot Tested
RAZBERRY CompatibilityYes
POPP CompatibilityYes
PIPER CompatibilityNot Tested
Compatibility with O2 Smart BoxNot tested

Write a review

Qubino 3-Phase Smart Meter (ZMNHXD1)
  • Qubino 3-Phase Smart Meter is used for energy measurements in three-phase electrical power network and can be used in residential, industrial and utility applications.
  • The device measures energy directly in 4-wire networks according to the principle of fast sampling of voltage and current signals.
  • It is designed to be mounted on DIN rail.

Write a review

 
Comments(6)
SmarterHOME Team 21.07.2022

bidirectional?

Dobrý deň,
zariadenie meria aj spotrebovanú aj produkovanú energiu.
Spotrebovaná energia je kladná.
Produkovaná energia je záporná hodnota so znamienkom mínus.
Ešte pozor nato, či Vaša riadiaca jednotka podporuje zobrazovanie zápornej hodnoty.
Pekný deň.

  • Was this comment useful to you?
  • (0) (0)
MN 21.07.2022

bidirectional?

Dobry den,

je mozne meracom merat aj smer toku energie?
Dakujem

  • Was this comment useful to you?
  • (0) (0)
SmarterHOME Team 14.07.2021

Výpadky komunikace s HC2 a chybějící výstup měření

Dobrý deň,
ďakujeme za recenziu produktu.
Sila signálu závísi od viacerých faktorov - vzdialenosti samotného zariadenia, vzdialenosti dostupných repeaterov, odrazov signálu kvôli železným prvkom a podobne.
Ak ste presunuli repeater len nedávno, chvíľu potrvá kým sa Z-Wave sieť ustabilizuje.
Pekný deň.
SH

  • Was this comment useful to you?
  • (0) (0)
Tomáš D 13.07.2021

Výpadky komunikace s HC2 a chybějící výstup měření

Měřič jsem si namontoval k měření spotřeby elektrického kotle, abych mohl příkon dlouhodobě sledovat.
Při používání se potýkám s dvěma problémy:
- vypdavá komunikace s HC2 a to jsem aktivní repeater dal 0,5m od rozvadeče a vyndal (dočasně( plechová dvířka
- nemá výstup měření výkonu typu S0 a nedá se napojit například na WATTrouter pro FVE

  • Was this comment useful to you?
  • (0) (0)
SmarterHOME Team 04.01.2021

Stabilita

Dobrý deň,
problémy so signálom u Qubino 3-Phase Smart Meter (ZMNHXD1) sme nezaregistrovali.
Pravdepodobne vo Vašom prípade to spôsobuje plechový rozvádzač, ktorý spôsobuje útlm Z-Wave signálu.
Odporúčame použiť plastové dvierka rozvádzača a ak je Qubino merač umiestnený ďalej od riadiacej jednotky, tak niekde na trasu medzi riadiacou jednotkou a Qubino meračom - umiestniť Z-Wave repeater (trvalo napájané Z-Wave zariadenie).

Ďakujeme za pochopenie.
Pekný deň.

  • Was this comment useful to you?
  • (0) (0)
Miloš K 03.01.2021

Stabilita

V HC3 vie vypadávať komunikácia. Či je to vplyvom plechového rozvádzača, vzdialenosťou alebo krátkou podporou v HC3 neviem.

  • Was this comment useful to you?
  • (0) (0)